This webinar will focus on reviewing both the Building Design and Interior Design Vignettes for the Schematic Design exam. Mike Newman will be reviewing the vignettes, and going over the strategies and resources for how to complete them.

Some of the code issues to be thinking about, one of them is the idea of the dead-end corridor. So dead-end corridor is essentially every building that you design in a commercial setting will end up being something like, there's a corridor and there's a stair at either ends. All right, so we got stairs that either end that way.

So the idea here is that there should always be an exit way, a stairway at the end either stair or a door directly out, if you're on the ground floor, to be able to get out of the building. Now not every building can you always have the stair or the door literally at the very very end, and so there's a little bit of allowance to have a bit of corridor space that goes past that exit door. So that corridor that's going passed that's referred to as a dead-end corridor, and they're saying 20 foot is the maximum.

My guess is the code will always be the same essentially but you should always read through it to make sure because they could change it, they could say 30 feet or they could say 10 feet or something. And they have changed things in the past at different points. So it's worth going through it but my guess is it's going to be 20 feet. So that means that if somebody is exiting this way and they miss that stair, they would go way down to the end here before they realize there wasn't an exit to get back.

So this and that looks longer than 20 feet to me, so first of all I could find a bunch of different ways to fix this as an issue. One is, instead of having that door there, maybe I put the door there so it's a little closer to the end. Maybe I put this door over here so that I'm less than 20, and if I don't need these corridor to go any further maybe I just end the corridor. So there's lots of ways you can deal with these things, we're not talking about very complicated ideas but that's one of the code issues, you can't go longer than 20 feet. Another code issue you're going to find, I believe I have it on the next... is this idea that they really like the fact that you exit straight from the stair stairwell.

So on the ground floor, one of the ways out should be people from the corridor on the first floor are going to be able to exit through the stair and then go right straight to the outside. They want you to be able to exit straight to the outside from that stairwell. So that has implication on to where you can put the stairs, that's an important thing to remember. And then kind of while we're looking at that, one of the things you realize is that all the Egress doors this is not all the doors, this is just all the doors that are categorize as Egress doors, will swing in the direction of Egress.

So in this particular example this is a stairwell on the ground floor and this is the corridor on the ground floor. If I'm exiting from the first floor, I would want to be able to go into the stairwell, so the door swings in the direction into the stairwell. And then I'd want to be able to exit straight out of that to the outside and so the door swings straight to the outside. It's swinging in the direction of the flow of Egress. If I'm coming down the stairs and I'm going into the ground floor well, that would be a situation that is not an Egress situation because if it's a fire, it's a panic and it's an egress situation. I'm not going to go into the building, I'm going to go straight out which means my swing out is going to work. So it's okay for the door to swing into that stairwell on that first floor.

So you start seeing very quickly that it gets a little complicated but not terribly complicated but not terribly complicated, just follow that rule that Egress doors swing in the direction of egress. That will show up on all the doors that are considered egress doors.

It's going to be large enough that the occupancy would require you to have more than one exit door. The sheer fact of that makes those two doors egress doors, because it's bumped up above the amount of occupancy that . . . so it now means it's considered anything exiting out of that space is considered an egress process. So all these other doors are all swinging into the rooms but this big room, the doors are swinging out into the corridor.  And that half of that distance is long as the doors are farther apart than that half of the diagonal, you're fine. Those are far enough apart from each other, they obviously don't want the doors to be right next to each other because if there's then problem you wouldn't be able to getaway from it.