Air Supply Heating System - Building Systems Mock Exam - Architect Registration Exam - ARE Live
4,468 views · Published 3 December 2015 · 6:46 · Indexed 10 November 2026
Channel: Black Spectacles · 2015 · Education
To view the related course, click here: http://bksp.es/yt-building-systems-11-11-15 Download the Mock Exam- http://bksp.es/building-systems-mock-exam-11-11-15 ARE Prep powered by Black Spectacles- blackspectacles.com/courses Mike's Recommended Resources to pass the ARE: http://blackspectacles.com/blog/books-need-to-pass-are-exam-resources So number two is essentially the same question, but for a different scenario. So designing a large, single-story manufacturing building for the air supply you would probably use A:...Then pretty much the same answer, central air-handling unit, individual fan coil unit, central chiller, chilled water loop, DX rooftop units. So all of those same reasons that we talked about before. This is actually the one where the DX unit on the rooftop is probably going to make a lot of sense. This is going to be the one where, if I have that great, big building and it's a big, single-story space, and I know that I've got various things happening in different locations. Certain kinds of warehousing, certain kinds of manufacturing, various other things, this would be a really easy place to just place, right up on that roof a big, self-contained DX unit. Maybe I have a couple of them, so you could have a different one over the warehouse area then, compared to the manufacturing area. You're just going to be blowing in a large volume of air. You're going to be taking in the return at the same spot. It's going to have the refrigerant built into it. It's going to have its heat rejection possibilities built into it. In this way manufacturing processes can change pretty readily. The idea that you could fairly simply say ten years down the road, realize that we're going to start manufacturing in a slightly different way, let's move it 50-feet over. You can lift it up and move it, and change it around. This is a very flexible, manipulative system that seems to fit to the single-story manufacturing use. Now with a DX unit you can certainly add quite a bit of controlling ductwork, and all of that to it. But one of the nice things about these rooftop units, you can also just dump in a lot of air. If I have enough ceiling height, it'll spread reasonably quickly and easily. So for all of the reasons that these central chiller and chilled loop water systems that we talked about previously, for all the reasons that was a good idea for those, for this one it seems actually in the way. It's probably just easier and better to have these cheaper, faster things that I can put up on the roof and get something straight out of it. Marc: Two questions. The first one is what does DX stand for? Mike: Good question. I was just about to get to that, but all right, good question. So a DX system, what we were looking at in the previous question. Sorry. It's going to take a second. I'm just going to go back for a quick second. What we were looking at in the previous question was a chiller and that chiller had a refrigerant loop and then it went onto two barrels, and this was all part of the chiller. It created a cold-water loop that went up and gave the chilled water to the air-handling units, wherever they were, anywhere around the building. And then the air-handling units have what's referred to as the airside loop. Not everybody calls them loops. I call them loops because I think it's the clearest way to think of it. So the air-handling loop blows air out into the space after it's been conditioned, then takes air back in through the return, and so it's its own loop. The chilled water is its own loop and then the heat rejection on the other side, the other barrel is its own loop. So this is a four-loop system. You've got the refrigerant is one, the cold water is two, the air is three, and the heat rejection is four. So I've got four loops. A DX system is one where I don't use the chilled water loop, so I have the other ones. I still have the airside loop. I still have the refrigerant loop. I still have the heat rejection loop in some form, but I don't need to have the chilled water because I'm not taking the cooling, and moving it around the building. I'm just having that DX unit up on the roof. There is going to be a great, big box and it's going to have within it a fan, a coil. That coil's going to have a refrigerant loop happening. That refrigerant loop is going to go and feed that coil directly and then it's going to go back in. So the refrigerant is getting cooled, and then by the process of the refrigerant getting cooled, and then blowing the fan directly across, it's blowing the air down into the building. Then I have right above that element in the same box, I have this device that has another fan. It's not always a fan, but let's just say it's a fan for our purposes here. It's going to be taking the excess heat that was created, and blow it right out of that big box.
More from this channel
-
4:13
3Axis Digital Fabrication | Kansas City | Black Spectacles
-
2:08
Speculations on Design Technology with Erin Rae Hoffer & Scott Simpson | Black Spectacles
-
3:22
David Fano and Steve Sanderson of Design By Many | Black Spectacles Interview
-
1:50
The Un-Competition Project | Black Spectacles
-
0:35
Revit Tutorial: Introduction to Curtain Wall Families in Revit Architecture | Black Spectacles
-
2:53
Revit Tutorial: Types of Curtain Walls | Black Spectacles
-
9:55
Revit Tutorial: Building a Stick Curtain Wall | Black Spectacles
-
0:36
Revit Tutorial: Introduction to Door Families in Revit Architecture | Black Spectacles