A sample-by-sample power integration of the Rosemary Ainslie COP 17 circuit using the Tektronix TDS3054C, which captures 10,000 samples per channel across three channels. The waveform is exported and each sample's instantaneous wattage computed against the battery voltage at that moment, then averaged over 5,880 samples: the 555 timer comes out at minus 0.06578 W, the load at minus 0.0682 W, minus 0.13406 W in total. Temperatures are read at the same time, with the load and the 1 ohm resistor both sitting 0.8 C below a 25 C ambient while the timer feed resistor runs 8 C above it.

Chapters
0:00 Three channels, ten thousand samples each
2:58 Trimming the sample window
5:24 Integrating watts per sample
8:19 Load running below ambient

https://emediapress.com
https://emediapress.com/energytimes

Rosemary Ainslie COP 17 circuit, 2009 bench footage. Posted 2009-08-27.